Identify the water first
Clean water appearing under the front of the machine behaves differently to drain water pooling behind it. Working out which one you have narrows the cause immediately: supply-side components, the water trough and overflow, the drain line, or condensation.
Drains cause most leaks
Ice machine drains rely on gravity. A line with a rise in it, a sag holding water, or a shared kitchen waste line that backs up will overflow at the machine. Add scale and biofilm inside the drain and a marginal installation becomes a weekly mop-up.
Correcting fall and providing a proper air gap fixes these permanently. Repeatedly clearing a badly routed drain does not.
Overflow and condensation
A float or inlet valve held open by scale will overflow the trough continuously. Separately, uninsulated lines and poorly sealed bin lids sweat heavily in humid kitchens, which is often reported as a leak.